Abstract

A sudden change in flow area induces complex transient processes in foams, which increase in significance with increasing flowrate. The effects are a function of the method of foam generation and, hence, depend on the initial foam structure. In vertical upflow at a sudden expansion or contraction, a substantial fraction of the liquid in the foam drains back upstream. This leads to a greatly reduced liquid holdup downstream and a recirculating flow regime upstream. For the area ratios of the fittings investigated, the extent of liquid holdup reduction was less pronounced in the case of a sudden contraction. At low gas rates, a plug flow regime usually existed on either side of the fitting; however, with an increase in gas throughput the presence of the fitting led to the establishment of a recirculating flow regime upstream. At sufficiently high flowrates complete breakdown of foam structure occurred resulting in the onset of a `flooding' regime downstream. Foam rheology was successfully described by a two-parameter power-law model, and the friction factor for foam flow could be described by a simple explicit relationship.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.