Abstract

In order to evaluate the effect of flux on membrane fouling, the performance of a bench-scale submerged membrane bioreactor (MBR) equipped with ultrafiltration membranes (ZENON®) was investigated under real conditions at different flux rates. The pilot plant was located at the wastewater treatment plant of the city of Granada (Spain). Influent used in the experiments came from the primary settling tank. Assays carried out under different operating conditions indicated that dTMP/dt increased in accordance with the increase in flux. The results showed a significant impact on the rate of transmembrane pressure, while the behavior of membrane fouling was logarithmic with respect to the flux. These findings could be of some importance for understanding the behavior of the membrane, since over 20.57 L m−2 h−1 the flux rate produced a significant increase in transmembrane pressure. The data therefore suggest that an increase in the net flux significantly affects membrane fouling.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.