Abstract
This paper describes a hybrid Flux Chamber-Soil Gas Probe methodology for measuring municipal solid waste (MSW) gas emission rates. Following the design of the flux chamber, the chamber was laboratory tested to define its mixing characteristics and optimum operating parameter values. Flux chamber operating parameters included: chamber pressure, sweep air flow rate, landfill surface insertion depth, and sweep air velocity. Optimum operating parameter values were determined by operating the flux chamber on a simulated subsurface emission source and varying the operating parameters. The laboratory tests indicated that the flux chamber could be operated to provide zero biasing of gas emission rates, resulting in accurate measurement of gas emission rates.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of the Air & Waste Management Association
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.