Abstract

Purpose: To compare the diagnostic accuracy and complication rates of fluoroscopyguided percutaneous transthoracic fine needle aspiration biopsy (FNAB) and core biopsy (CB). Materials and Methods: Ninety-one fluoroscopy-guided lung biopsies were performed in 86 patients using a 22-gauge fine needle (n=52) or a 21-gauge automated cutting needle (n=39). The size of pulmonary lesions were 1-9 cm. Histologic diagnosis rates and complications rates of the two groups were compared. Results: The overall sensitivity of FNAB was 98% (51/52) which was higher than that of CB 89.7% (35/39) (p=0.160, Fisher's exact test). For the diagnosis of malignancy, sensitivities of FNAB and CB were 97.2% (35/36) and 89.7% (26/29), respectively (p=0.316). For the diagnosis of benignancy, sensitivities of FNAB and CB were 100% (16/16) and 90% (9/10), respectively (p=0.384). The specific histologic diagnosis rate of CB was 80% (8/10) in benignancy, which was higher than that of FNAB 56% (9/16) (p=0.398). The pneumothorax rates were 7.7% (4/52) for FNAB and 15.4% (6/39) for CB (p=0.316). Conclusion: Although not statistically significant, a higher overall sensitivity was found in fluoroscopy-guided FNAB in the diagnosis of both malignancy and benignancy, and FNAB also achieved lower complication rates. More specific histologic diagnoses were obtained with CB.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call