Abstract
A micro-fluorometric ELISA which required only 50 μl of reagent in each step is reported here for rapid detection of anti-estrogen receptor (ER) antibody production by hybridoma cultures. In this study, several factors which influence the sesitivity of ELISA, e.g., incubation time, substrates, microtiter plates, concentration of coating antigens, choice and concentration of specific antibody and enzyme were evaluated. We observed that micro-fluorimetric ELISA using 4-methylumbelliferyl phosphate-phosphatase system and MicroFluor W plates was the most sensitive; it detected readily 1 ng coating antigens or 1 ng antibody during a 15 min incubation. This system was used successfully for the detection of anti-ER antibodies in mouse immune sera, and in spent media from in vitro immunized spleen cells or hybridoma cells. This method is simple, sensitive, rapid and reliable for ER or anti-ER antibody determination.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.