Abstract

Hemostasis is the cessation of bleeding due to the formation of a blood clot. After the completion of wound healing, the blood clot is typically dissolved through the natural process of fibrinolysis, the enzymatic digestion by plasmin of the fibrin fibers that make up its structural scaffold. In vitro studies of fibrinolysis reveal mechanisms regulating these processes and often employ fluorescent microscopy to observe protein colocalization and fibrin digestion. In this study, we investigate the effects of labeling a fibrin network with 20 nm diameter fluorescent beads (fluorospheres) for the purpose of studying fibrinolysis. We observed fibers and 2-D fibrin networks labeled with fluorospheres during fibrinolysis. We found that the labeling of fibrin with fluorospheres can alter fibrinolytic mechanisms. In previous work, we showed that, during lysis, fibrin fibers are cleaved into two segments at a single location. Herein we demonstrate that fibrinolysis can be altered by the concentration of fluorospheres used to label the fibers, with high concentrations of fluorospheres leading to very minimal cleaving. Furthermore, fibers that are left uncleaved after the addition of plasmin often elongate, losing their inherent tension throughout the imaging process. Elongation was especially prominent among fibers that had bundled together due to other cleavage events and was dependent on the concentration of fluorophores used to label fibers. Of the fibers that do cleave, the site at which they cleave also shows a predictable trend dependent on fluorosphere concentration; low concentrations heavily favor cleavage locations at either end of fibrin fiber and high concentrations show no disparity between the fiber ends and other locations along the fiber. After the initial cleavage event bead concentration also affects further digestion, as higher bead concentrations exhibited a larger population of fibers that did not digest further. The results described in this paper indicate that fluorescent labeling strategies can impact fibrinolysis results.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.