Abstract

Can non-invasive imaging with fluorescence lifetime imaging microscopy (FLIM) detect metabolic differences in euploid versus aneuploid human blastocysts? FLIM has identified significant metabolic differences between euploid and aneuploid blastocysts. Prior studies have demonstrated that FLIM can detect metabolic differences in mouse oocytes and embryos and in discarded human blastocysts. This was a prospective observational study from August 2019 to February 2020. Embryo metabolic state was assessed using FLIM to measure the autofluorescence metabolic factors nicotinamide adenine dinucleotide dehydrogenase together with nicotinamide adenine phosphate dinucleotide dehydrogenase (NAD(P)H) and flavin adenine dinucleotide (FAD). Eight metabolic FLIM parameters were obtained from each blastocyst (four for NAD(P)H and four for FAD): short (T1) and long (T2) fluorescence lifetime, fluorescence intensity (I) and fraction of the molecules engaged with enzymes (F). The redox ratio (NAD(P)H-I)/(FAD-I) was also calculated for each image. This study was performed at a single academically affiliated centre where there were 156 discarded frozen blastocysts (n = 17 euploids; 139 aneuploids) included. Ploidy status was determined by pre-implantation genetic testing for aneuploidy (PGT-A). Discarded human blastocysts were compared using single FLIM parameters. Additionally, inner cell mass (ICM) and trophectoderm (TE) were also evaluated. Multilevel models were used for analysis. A post-hoc correction used Benjamini-Hochberg's false discovery rate, at a q-value of 0.05. Comparing euploid (n = 17) versus aneuploid (n = 139) embryos, a significant difference was seen in NAD(P)H-F (P < 0.04), FAD-I (P < 0.04) and redox ratio (P < 0.05). Euploid ICM (n = 15) versus aneuploid ICM (n = 119) also demonstrated significantly different signatures in NAD(P)H-F (P < 0.009), FAD-I (P < 0.03) and redox ratio (P < 0.03). Similarly, euploid TE (n = 15) versus aneuploid TE (n = 119) had significant differences in NAD(P)H-F (P < 0.0001) and FAD-I (P < 0.04). This study utilized discarded human blastocysts, and these embryos may differ metabolically from non-discarded human embryos. The blastocysts analysed were vitrified after PGT-A biopsy and it is unclear how the vitrification process may affect the metabolic profile of blastocysts. Our study was also limited by the small number of rare donated euploid embryos available for analysis. Euploid embryos are very rarely discarded due to their value to patients trying to conceive, which limits their use for research purposes. However, we controlled for the imbalance with the bootstrap resampling analysis. These findings provide preliminary evidence that FLIM may be a useful non-invasive clinical tool to assist in identifying the ploidy status of embryos. The study was supported by the Blavatnik Biomedical Accelerator Grant at Harvard University. Becker and Hickl GmbH and Boston Electronics sponsored research with the loaning of equipment for FLIM. D.J.N. is an inventor on patent US20170039415A1. There are no other conflicts of interest to declare. N/A.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.