Abstract

Uptake of fluorescein isothiocynate-dextran (FITC-dextran) by Chinese hamster ovary cells was studied after exposure to ultrasonic standing wave (USW) in presence of Optison®, an ultrasound contrast agent. Confluent Chinese hamster ovary cells were harvested and suspended in phosphate-buffered saline + 0.1% bovine serum albumin containing FITC-dextran (10, 40, and 500 kDa) at 10 μM final concentration. The suspension was seeded with contrast agent (75 μL/mL) and exposed to a 1.5 MHz USW system at acoustic pressures ranging from 0.98 to 4.2 MPa. Macromolecular uptake was assessed by fluorescent microscopy and quantified by flow cytometry 10 min after exposure. FITC-dextran positive cells, as assessed by flow cytometry, were 1 ± 0.05% and 2.58 ± 0.27% for acoustic pressures of 1.96 and 4.2 MPa, respectively ( p = 0.006). Fluorescent microscopy indicated a degree of macromolecular loading at 0.98 MPa with 46% of peripherally FITC-dextran- and/or propidium iodide-stained cells coincident with the appearance of significant frequency ( f 0/2 and 2 f 0) emission signals. At higher pressures, high macromolecular loading with 6% peripherally stained cells at 1.96 MPa was associated with lower order emission signals and white noise. The study conclusively demonstrates macromolecular loading in an USW, a significantly higher macromolecular loading at higher pressures and indicates potential of emission signals for a feedback loop to control the acoustic power outputs and fine-tune the biologic effects associated with sonoporation. (E-mail: AmsoNN@cf.ac.uk)

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call