Abstract

A new method is presented for calculating a building-specific subslab to indoor air attenuation factor for use in assessing subsurface vapor intrusion to indoor air. The technique includes (1) subslab gas extraction with flow and vacuum measurements and mathematical modeling to characterize the bulk average vertical gas conductivity of the floor slab, (2) monitoring of the ambient pressure gradient across the floor slab with a micromanometer, (3) calculating the volumetric flow of soil gas into the building ( Qsoil), and (4) dividing Qsoil by the building ventilation rate ( Qbuilding) to calculate a building-specific attenuation factor. Sample calculations using order statistics from 121 individual tests are comparable to the U.S. Environmental Protection Agency empirical attenuation factors for residential buildings and the U.S. Navy empirical attenuation factors for commercial/industrial buildings. A case study of a commercial building shows encouraging agreement between the attenuation factors calculated via this method and via conventional subslab and indoor air sampling.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.