Abstract

Fluid dynamic gauging (FDG) was used to track the thickness of the cake layer formed during the microfiltration of a 45° Brix molasses solution using a 1.5μm polysulphone membrane. A simultaneous measure of flux and deposit thickness throughout the full membrane operating cycle is reported. Asymptotic fouling thicknesses of ca. 100μm are developed after 30min of filtration. Accordingly, flux declines are severe at ca. 93%. Permeate line closed (PLC) operation leads to the complete removal of the deposit layer, and the recovery of 60% of the flux. However, permeate line open (PLO) operation leads to only a 50% flux recovery and an asymptotic deposit thickness of 10μm. An initial increase and subsequent reduction in flux during chemical cleaning has also been recorded for both acid and alkali cleaning regimes. Effective cleaning regimes for membranes fouled by molasses require an alkali stage followed by an acid stage.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.