Abstract

A flow visualization and thermal stratification study with localized heat sources was performed using Freon 113 and water individually as the test liquids. The experiments were conducted at atmospheric pressure with the liquids in the subcooled state. Flow visualization results were obtained with a schlieren-photographic system using a horizontal cylinder. A vertical cylinder was used for measuring the temperature profiles. The flow patterns and the thermocline development were strongly linked to the heater location. Three internal baffle arrangements were tried in the horizontal cylinder but they did not affect the thermocline location.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.