Abstract

AbstractIn this work, the annular (tangential) flow of Newtonian and non‐Newtonian fluids in tube bundles has been studied experimentally. Extensive pressure drop data has been obtained embracing wide ranges of the Reynolds number (13–6600) and for two test modules of different geometrical arrangements, but of similar overall void fraction. Preliminary experiments suggest that the pressure drop is mainly determined by the overall void fraction of the bundle and is relatively insensitive to the detailed geometrical configuration of the bundle. A simple predictive correlation has been developed which reconciles the present results for Newtonian and power law fluids with acceptable levels of reliability.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.