Abstract

We experimentally studied shear flow of a water-based magnetic fluid between concentric annuli. The experiment was carried out by changing the angular velocity of the outer cylinder, and the moment acting on the inner cylinder was measured. Experimental results were discussed in the following three ways. At first the magnetic fluid was treated as a Newtonian fluid, and a small difference in the flow curves was found. Next the power-law fluid theory was applied in order to explain these differences. Finally we examined this flow problem using the micropolar theory, which gives the theoretical relation between the moment acting on the inner cylinder and the angular velocity of the outer one. We measured the coefficient which denoted the micropolar effect, and showed the influence of the substructure on the fluid.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.