As California's dairy industry continues to grow, manure management has become an increasingly important issue for dairy producers, government regulators and the public living in close proximity to dairies. Dairies are increasingly required to prepare nutrient management plans and comply with regulations concerning their manure management practices. A common dairy practice in California is to house the cows in free stall barns with water flush systems to remove the manure. The manure flush water, high in nutrients such as nitrogen and phosphorus, is collected in holding ponds until it can be combined with freshwater and applied to cropland during irrigation. Being able to quantify the amount of manure water applied is critical to good nutrient management of crops. The high trash and debris content of manure water has precluded the use of most flow meters commonly used in agriculture, such as the propeller meter. A field test of electromagnetic flow meters and a Doppler flow meter determined that both were accurate, dependable and appropriate for measuring manure-water flow rates. Their drawbacks are price ($3,000 to $4,000) and the need for electrical power for permanent flow-meter installations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.