Abstract

Flow rate is one of the most important parameters in hydraulic systems. This paper present a non-interposition flow measurement method for hydraulic systems, based on Acoustic Emission (AE) technology, by fixing an AE detector after the bend of the pipelines. The relationships between AE signals and the flow rate were investigated. Results show that the Root-Mean-Squared (RMS) values of the AE signals and AE energy could be used in hydraulic system, for flow measurement under specified system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.