Abstract

ObjectiveThe objective of this study was to investigate the hemodynamic parameters of type II endoleaks (T2ELs) to predict sac expansion using four-dimensional flow-sensitive magnetic resonance imaging (4D-flow MRI) analysis. MethodsPatients who underwent endovascular aneurysm repair (EVAR) and were diagnosed with a T2EL were included in the study. Using 4D-flow MRI at 7 days, the peak flow velocity and amplitude of dynamics of blood flow per minute were measured in each T2EL vessel. The peak flow velocity was defined as the maximum of the absolute value of the blood flow velocity. The amplitude of dynamics of blood flow in the tributary arteries was defined as the sum of the absolute values of the inflow and outflow volume in each vessel. The amplitude of dynamics of blood flow in the tributary arteries per sac was calculated in each sac. The aneurysm sac diameter was measured by computed tomography (CT) at 1 year. The patients were divided into two groups according to the presence or absence of sac expansion. ResultsOf 155 patients who underwent EVAR, both CT angiography and 4D-flow MRI were performed in 107 patients at 7 days after EVAR. Among them, 39 (36.4%) were found to have a T2EL, of whom 28 were re-evaluated with CT angiography and 4D-flow at 1 year; 7 patients had expanding sacs (expanding group), whereas 21 had nonexpanding sacs (not-expanding group). At 7 days, 28 patients had 80 T2EL vessels detected by 4D-flow MRI, of which 39 vessels (48.8%) had stopped flowing at 1 year (transient vessels); 41 vessels (51.3%) had sustained flow (persistent vessels). The persistent vessels had significantly larger peak flow velocity and amplitude of dynamics of blood flow. The comprehensive analysis of T2EL vessels per sac identified that the amplitude of dynamics of blood flow in the tributary arteries per sac was significantly higher in the expanding group than in the not-expanding group. A receiver operating characteristic curve analysis revealed that the sensitivity and specificity of sac enlargement at a cutoff value of 3750 mm3/min were 85.7% and 76.2%, respectively. ConclusionsThe fate of aneurysm sacs with T2ELs after EVAR has remained difficult to predict. A comprehensive analysis of concurrent multiple T2EL vessels using 4D-flow MRI analysis may enable prediction of the sac expansion after EVAR.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.