Abstract

A small part of cellular iron, usually called ‘labile iron pool’ (LIP), is not securely stored and has the potential to catalyse the formation of highly reactive oxygen species. The present work estimated LIP levels in human white cells by using the analytical power of flow cytometry. The method relies essentially on already established principles but has the added value of monitoring LIP in different subpopulations of human blood cells concurrently in a single sample. Examination of 41 apparently healthy individuals revealed a positive correlation between LIP levels and the age of the donors (r=0.656, 0.572 and 0.702 for granulocytes, lymphocytes and monocytes, respectively, p<0.0001), indicating that cells of older individuals are prone to oxidations in conditions of oxidative stress. It is suggested that LIP estimation may represent a valuable tool in examinations searching for links between iron and a variety of oxidative stress-related pathological conditions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.