Abstract

This paper presents an experiment of flow control by supersonic pulsed jets in a very aggressive -duct typical of modern fighter aircraft engine inlet ducts. The Mach number in the aerodynamic interface plane ranges from 0.2 to 0.4, which is realistic from an application point of view. It was shown that, with continuous blowing, the flow could be fully reattached. The sensitivity of the distortion coefficient to the jet frequency was also clearly evidenced. Surprisingly, it is recommended to avoid actuating the jets at the natural frequencies present in the separated zone of the uncontrolled flow. Besides, it is observed that pulsed jets actuation increases the unsteady flow distortion. Furthermore, in the uncontrolled flow, a lateral movement of the structures associated with high total pressure losses in the aerodynamic interface plane was highlighted.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.