Lead and lead-alloys are proposed in future advanced nuclear system as coolant and spallation target. To test the natural circulation and gas-lift and obtain thermal-hydraulics data for computational fluid dynamics (CFD) and system code validation, a lead–bismuth eutectic rectangular loop, the KYLIN-II Thermal Hydraulic natural circulation test loop, has been designed and constructed by the FDS team. In this paper, theoretical analysis on natural circulation thermal-hydraulic performance is described and the steady-state natural circulation experiment is performed. The results indicated that the natural circulation capability depends on the loop resistance and the temperature and center height differences between the hot and cold legs. The theoretical analysis results agree well with, while the CFD deviate from, the experimental results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.