Abstract

The present work reports on flow boiling visualization of refrigerant R-134a in a vertical circular channel with an internal diameter of 1.33 mm and 235 mm in heated length. A quartz tube with a homogeneous Indium Tin Oxide coating is used to allow heating and simultaneous visualization. Flow patterns have been observed along the heated length with the aid of high-speed complementary metal oxide semiconductor (CMOS) digital camera. From the flow boiling visualization, seven distinct two-phase flow patterns have been observed: isolated bubbly flow, confined bubbly flow, slug flow, churn flow, slug-annular flow, annular flow, and mist flow. Two-phase flow pattern observations are presented in the form of flow pattern maps. The effects of the saturation temperature and the inlet subcooling degree on the two-phase flow pattern transitions are elucidated. Finally, the experimental flow pattern map is compared with models developed for conventional sizes as well as to a microscale map for air-water mixtures available in literature, showing a large discrepancy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.