Non-contacted double-walled-straight-tube heat exchanger has been designed for the Lead-Bismuth Eutectic (LBE) loop KYLIN-II, the flow rate and temperature distribution dramatically influence the performance of heat exchanger. The Computational Fluid Dynamics (CFD) and numerical heat transfer method has been used to build the three-dimensional model of the heat exchanger. Adopting the SST (Shear Stress Transport) k-omega model the flow rate and temperature distribution of the heat exchanger model has been calculated. The numerical simulation result shows that the non-uniform LBE flows don’t affect TH performance of HX filled with powder in the gap between two tubes.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.