Abstract
Energy-saving ability and high flotation efficiency are two important factors in the flotation process. In this investigation, a new concept for the flotation process design based on energy input and distribution was proposed, low energy was inputted early to recover easy-to-float materials, whereas high energy was inputted late to recover difficult-to-float materials. The flotation tests were conducted in an XFD 0.75L laboratory-scale flotation machine. A comparison of flotation performance using constant power input and gradually increased power input was investigated. The flotation results indicated that low ash content, high flotation efficiency index, and energy-saving ability could be obtained by increasing power input step by step in the flotation process. The flotation process design based on different shaft speeds (1500, 1500, 1800, 1800, and 2400r/min in different flotation periods) and an energy consumption of 1720.8J is suitable for flotation performance of the coal samples in this study.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.