Abstract

The electronic search was completed within PubMed database from 2 June 2011 to 2 June 2022. English-language papers investigating the flexural strength of IPS e.max CAD, Celtra Duo, Suprinity PC, and n!ce CAD/CAM blocks were included in the search strategy. From 211 potential articles, a total of 26 were identified for a comprehensive analysis. Categorization per material was carried out as follows: IPS e.max CAD (n = 27), Suprinity PC (n = 8), Celtra Duo (n = 6), and n!ce (n = 1). The three-point bending test (3-PBT) was used in 18 articles, followed by biaxial flexural test (BFT) in 10 articles, with one of these using the four-point bending test (4-PBT) as well. The most common specimen dimension was 14 × 4 × 1.2 mm (plates) for the 3-PBT and 12 × 1.2 mm (discs) for BFT. The flexural strength values for LSGC materials varied widely between the studies. As new LSGC materials are launched on the market, clinicians need to be aware of their flexural strength differences, which could influence the clinical performance of restorations.