Abstract

The flexural behavior of corroded reinforced concrete (RC) beams strengthened with textile reinforced concrete (TRC) was analyzed and discussed in this work. Thirteen beams, including one reference beam, three corrosion-only beams, and nine TRC-strengthened corroded beams, were tested under four-point bending. The failure modes, cracks, bearing capacity, load–displacement curves and ductility of the tested beams were analyzed. The results showed that the TRC played a role in increasing the number of cracks and decreasing the width of the cracks in the corroded RC beams. In terms of improving the bearing capacity, TRC can improve the bearing capacity of corroded beams even more than the reference beams, and the strengthening after removing the concrete cover of corroded RC beams is better than direct strengthening. The corroded beams after TRC strengthening exhibited improved ductility. The energy absorption index of the TRC-strengthened corroded RC beams increased with the increase in the number of textile layers.