Abstract

Seven half-scale post-tensioned precast concrete beams were tested under anti-symmetrical flexure. The experimental parameters were shear span ratio and shear reinforcement ratio. Multi-strands and high strength shear reinforcement with nominal yield strength of 785 MPa were used as post-tensioning steel and shear reinforcement, respectively. Yielding of shear reinforcement was not observed in any of the specimens. The flexural capacity evaluated by the ACI rectangular concrete stress block with plane section assumption agreed well to the experimental results. The shear capacity was estimated by the design equation 71.2a in the AIJ Standard for Structural Design and Construction of Prestressed Concrete Structures. The experimental results collected by literature survey to past research revealed that shear failure modes could be related to each of the experimental parameters (shear span ratio, shear reinforcement strength and shear reinforcement ratio).