Abstract

Recently, FlexRay was developed to replace controller area network (CAN) protocol in chassis networking systems, to remedy the shortage of transmission capacity and unsatisfactory real-time transmission delay of conventional CAN. FlexRay network systems require correct synchronization and complex scheduling parameters. However, because platform configuration register (PCR) setting and message scheduling is complex and bothersome task, FlexRay is more difficult to implement in applications than CAN protocol. To assist a network designer for implementing FlexRay cluster, this paper presents an analysis of FlexRay platform configuration register and automatic generation program of PCR. To demonstrate the feasibility of the automatic generation program, we evaluated its performance using experimental testbed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.