Abstract

Ten normal ring fingers from ten donors were used to determine the effect of flexor tendon repair on the gliding resistance between the tendon and the A2 pulley. Gliding resistance was measured for the intact FDP tendon and for the same tendon after it was cut transversely and repaired with a 4/0 Ticron core suture and a 6/0 running epitendinous nylon suture. After repair, the gliding pattern of the tendon through the A2 pulley changed significantly. The resistance and the friction coefficient were approximately doubled (P < 0.005).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.