Abstract

As part of the Oak Ridge National Laboratory's Heavy-Section Steel Technology Program, studies have been conducted to determine flaw density in a section of reactor pressure vessel cut from the Hope Creek Unit 2 vessel. This boiling water reactor vessel was never in service. One objective was to evaluate the approximate 0.7- by 3-m (2- by 10-ft) segment of the vessel provided using ultrasonic flaw detection methods performed with both ASME Code techniques and supplemental ultrasonic methods. A second objective was to evaluate the inner surface stainless steel cladding for cracks with a high sensitivity penetrant examination. Both objectives were successfully completed. Five Code-recordable indications were detected ultrasonically; however, all were found to be anomalies associated with the cladding. One flaw was detected by the supplemental ultrasonic tests, and it was analyzed destructively. This flaw was pipelike indication, about 20 mm (0.8 in.) long extending along the length of the longitudinal weld in which it was located and was about 20 mm below the cladding surface. The flaw had a through-wall dimension (or length) of about 6 mm (0.24 in.) for an approximate 3-mm (0.1-in.) distance along the 20-mm major length. No flaws were detected by the penetrant examination of the cladding surface.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call