Abstract
This paper presents first results in the attempt to control a dual coil solenoid valve by means of a flatness based approach. First the modeling effort is described, then the differential flatness of the system is shown. The modeling results revealed that the system lacks controllability, when considering one coil only for actuating the valve. Therefore a suitable strategy for energizing both coils has been developed. The flatness property then is used to design feasible reference trajectories for the spool motion with the following properties: soft-landing of the spool, minimal driving current, feasible subject to voltage constraints. Simulation results demonstrate the usefulness and robustness of the approach.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.