Abstract

The dc breakdown field strength of copper electrodes separated by an epoxy-glass insulator in air shows a -0.04 (1/25) power dependence on the length of the electrode-insulator-gas triple junction in the range 10-2-102 cm. The breakdown field strength was found to have an electrode-gap spacing power dependence of -0.45 in the range ~ 10-3-~10-1 cm. This is a similar power factor to both that of the Paschen curve for air at atmospheric pressure and for dc-and microsecond-pulsed discharges over insulating surfaces in vacuum. These results may be applicable to various surface discharge switches and surface discharge plasma sources.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.