Abstract

To prevent flame flashback in swirl-stabilized, lean premixed combustion, a nonswirling air jet is introduced on the central axis of the radial swirl generator. This axial injection of air alters the flowfield as required for flashback-resistant combustion of premixed hydrogen. This study evaluates the impact of axial injection on the isothermal flowfield in a water tunnel by particle image velocimetry. Atmospheric reacting tests with hydrogen for inlet temperatures up to 620 K and up to stoichiometric conditions show a substantial increase in flashback resistance for the burner setup with axial injection. To verify the increase in flashback resistance to not be achieved at the expense of increased emissions, fuel–air mixing is evaluated in a water tunnel by planar laser-induced fluorescence of a fuel tracer. Even for high axial injection rates, the recorded unmixedness and emissions are uncorrelated. This results in single-digit emissions below adiabatic flame temperatures of 2000 K. Consequently, axial injection significantly extends the operational range of the combustor without increasing the emissions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.