Abstract
Abstract Experimental composition and flammabiliiy-limit data at one atmosphere for samples of dry low-Btu gases containing the major constituents CO, H2, CH4, N2, and CO2, from an actual in-siut coal gasification test are given. Also shown are composition and flammability-limit data for a synthetic low-Btu gas (simulating a type derived from coalrpar; to which CO2 and N2 were systematically added until the upper and lower flammability limits nearly converged. The flammability limits can be approximated by application of Le Chatelier's law, although it is more inaccurate than previously described in the literature. Fuel concentrations at both the upper and lower limits of the mixtures tested arc consistently leaner than predicted
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.