The flame extinction limits of syngas (H2‐CO) flames were measured using a twin-flame counterflow burner. Plots of extinction limits (%f: volumetric percent of fuel in air) versus global stretch rates were generated at different fuel blend compositions and were extrapolated to determine the flame extinction limit corresponding to an experimentally unattainable zero-stretch condition. The zero-stretch extinction limit of H2‐CO mixtures decreases with the increase in H2 concentration in the mixture. The average difference between the measured flame extinction limit and the Le Chatelier’s calculation is around 7% of the mean value. The measured OH chemiluminescence data indicates that regardless of blend composition the OH radical concentration reduces to a critical value prior to the flame extinction. The measured laminar flame velocity close to the extinction indicates that regardless of fuel composition, the premixed flame of hydrogen fuel blends extinguishes when the mixture laminar flame velocity falls below a critical value.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.