Abstract

Abstract Total chromium and Cr(VI) contents of cigarettes, ash, and smoke formed while burning cigarettes were determined. The determinations of chromium species were carried out according to procedures developed earlier. Cr(VI) was determined in a combined system, which involves a flow injection (FI) sorption preconcentration system, hydraulic high-pressure nebulization (HHPN) sample introduction technique, and flame atomic absorption spectrometric (FAAS) detection. The total chromium of samples in Cr(VI) form was determined in this same combined system after ashing cigarettes at 800°C [after total conversion of Cr(III) of the sample to Cr(VI)]. It was found that while burning cigarettes 0.8–1.2% of the original chromium content of the cigarettes comes to smoke in the toxic Cr(VI) form.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.