Abstract

To quantify fixation stability in patients with neovascular age-related macular degeneration (nAMD) at baseline, 3 and 6months after anti-vascular endothelial growth factor (anti-VEGF) treatment and furthermore asses the implications of an unsteady fixation for multifocal electroretinography (mfERG) measurements. Fifty eyes of 50 nAMD patients receiving intravitreal anti-VEGF treatment with either bevacizumab or ranibizumab and eight eyes of eight control subjects were included. Fixation stability measurements were performed with the Eye-Link eyetracking system and the retinal area in degrees2 (deg2) containing the 68% most frequently used fixation points (RAF68) was calculated. MfERG P1 amplitude and implicit time were analyzed in six concentric rings and as a summed response. Patients were examined at baseline, 3 and 6months. Four different mfERG recordings were performed for the control subjects to mimic an involuntary unstable fixation: normal central fixation, 2.4°, 4.8°, and 7.1° fixation instability. For control subjects, a fixation instability of 2.4° (corresponding to the central hexagon) did not reduce mfERG ring amplitudes significantly, whereas 4.8° and 7.1° fixation instability reduced the amplitudes significantly in rings 1 and 2 (p < 0.001) as well as in the peripheral rings in the 7.1° instability condition (p < 0.001). Fixation stability improved non-significantly for patients at 3 and 6months. The size of the retinal area of fixation was at baseline, 3 and 6months negatively correlated to visual acuity (VA) (rbaseline = -0.65, r3 months = -0.60, and r6 months = -0.66 respectively, p < 0.001) and mfERG amplitudes of the three innermost rings (rbaseline = -0.29, p = 0.042, r3months = -0.43, p = 0.003 and r6months = -0.31, p = 0.042). The VA cutoff for a fixation area less than 5deg2 (approximately the central hexagon) was 65, 77, and 68 ETDRS letters (corresponding a maximal Snellen equivalent of 0.31) at baseline, 3 and 6months, respectively. MfERG amplitudes in recordings of nAMD patients are at substantial risk of being reduced due to poor fixation as a large number of patients may use a fixation area of more than 5deg2. Fixation monitoring during recording as well as interpretation of results should be performed with care, especially in patients with poor visual acuity.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call