Abstract
Based on industrial experiment and analysis of theoretical calculation, the paper shows that it will be always unsuitable for thermocouple to be fixed on any sites of the desorption column if the established value of temperature-controlling apparatus is just the same temperature as is required to desorption process. When the thermocouple is fixed on the bottom of the desorption column or on any sites of the heating apparatus, the heating apparatus will have to switch frequently. The result should also be avoided in production concerned. The site of the thermocouple and its established value can be only determined finally through industrial experiment and theoretical calculation since they are connected with many conditions necessary to the desorption operation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.