Abstract

One hundred and thirty-six patients (June 1979, through May 1984) underwent mitral, aortic or double valve replacement and apico-aortic bypass with the St. Jude Medical (SJM) prosthesis, at Ryukyu University Hospital, Okinawa. Operative mortality for the entire group was 4.4 per cent. Late mortality from 1979-1984 was 6.1 per cent. There were no deaths related to mechanical failure. Warfarin anticoagulation was recommended for all patients. The incidence of thromboembolism was 0.76/100 patient years. Post operative catheterization studies in 21 patients one year after operation showed a satisfactory recovery of cardiac function. The SJM valve seems to be the satisfactory artificial valve in present use.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.