Abstract

We aimed to assess long-term safety and performance of the Orsiro sirolimus-eluting coronary stent with biodegradable polymer in a large unselected population and in pre-specified subgroups. BIOFLOW-III is a prospective, multicenter, international, observational registry with follow-up visits scheduled at 6 and 12 months, and at 3 and 5 years (NCT01553526). 1356 patients with 1738 lesions were enrolled. Of those, 392 (28.9%) declined to participate in the study extension from 18 months to 5 years, 37 (2.7%) withdrew consent, and 89 (6.6%) were lost to follow-up. At 5-years, Kaplan-Meier estimates of target lesion failure, defined as a composite of cardiac death, target-vessel myocardial infarction, coronary artery bypass grafting and clinically driven target lesion revascularization was 10.0% [95% confidence interval (CI): 8.4; 12.0] in the overall population, and 14.0% [95% CI: 10.5; 18.6], 10.3% [95% CI: 7.8; 13.5], 1.8% [95% CI: 0.3; 12.0], and 11.3% [95% CI: 8.5; 15.1] in the pre-defined risk groups of patients with diabetes mellitus, small vessels ≤2.75 mm, chronic total occlusion, and acute myocardial infarction. Definite stent thrombosis was observed in 0.3% [95% CI: 0.1; 0.9] of patients. These long-term outcomes provide further evidence on the safety and performance of a sirolimus-eluting biodegradable polymer stent within daily clinical practice. The very low definite stent thrombosis rate affirms biodegradable polymer safety and performance.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call