Abstract

Five equally spaced wavelengths from a multimode semiconductor laser diode source are used to provide five phase shifted intensity outputs from a low finesse Fabry-Pérot interferometer, from which the absolute phase, modulo 2π, can be determined. The use of five measurements is shown to reduce the phase errors arising from multiple reflections by two orders of magnitude compared to techniques using two or three intensity outputs. In addition, errors arising from miscalibration of the cavity are also reduced by up to two orders of magnitude compared to two, three and four phase shifted intensity outputs. Phase errors are discussed and the technique is demonstrated for temperature measurement. A 70°C range and 0.07°C resolution are obtained.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.