Abstract
Abstract Sour environments differ significantly in their aggressiveness toward materials, depending on such factors as total system pressure, partial pressures of hydrogen sulfide (H2S) and carbon dioxide (CO2), pH of the aqueous phase, temperature, chloride ion (Cl−) concentration, etc. Materials that perform poorly in standard laboratory sulfide stress cracking and hydrogen-induced cracking tests and some field environments may give acceptable performance under other sour service conditions. This paper provides some additional guidance on the manner in which standard sour service testing methods should be selected and performed, and on the interpretation and application of the results. The relevant recommendations and requirements of NACE International, the European Federation of Corrosion (EFC), and the American Petroleum Institute (API) are reviewed. The recommendations of NACE, EFC, and API for the selection of the most appropriate test method(s), test frequency, and acceptance criteria for particula...
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.