Abstract
Since cast titanium prostheses have many drawbacks, multi-directionally forged titanium grade 2 (MDF) was developed, and the application of the milling process was proposed for improving the titanium clasp. This in vitro study evaluated milled titanium clasps, including MDF titanium. Milling clasps were manufactured with commercially pure (CP) titanium grade 2 (CP 2), grade 4 (CP 4), Ti-6-Al-4V, and MDF. As a control, a CP 2 cast titanium clasp was fabricated in the conventional manner. No porosities and catastrophic failures were observed in the four milled titanium clasps. Fitness accuracy and retentive forces of milled CP 2 and CP 4 tended to be worse, and the milled MDF showed the higher retentive forces (12.45 N) than did cast and milled CP 2 clasps (9.32 N and 4.42 N). Milled titanium clasps can be recommended for longer-term clinical use as compared to cast clasps.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.