Abstract
High gradient performances of bulk niobium cavities go through a low-temperature baking during one or two days, the temperature parameter is adjusted in a narrow tuning range around 110 or 120 °C. With such treatment, the intrinsic quality factor Q 0 is improved at high fields. Assuming the oxygen diffusion is involved in this phenomenon, we have developed the “fast baking” (145 °C/3 h) as an alternative method. Similar results have been achieved with this method compared to standard baking. Consequently, for the first time, a link between oxygen diffusion and high field Q-slope has been demonstrated. Furthermore, this method open the way to a simpler and better baking procedure for the large-scale cavity production due to: • time reduction and • possibility to combine baking and drying during cavity preparation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.