Abstract

A Compton camera system consisting of a silicon drift detector (SDD) and an Anger camera has been constructed to study coincidence events and the possibility of tracking a recoil electron. An event is considered as a coincidence when a photon emitted from a radioactive source is first Compton scattered in the SDD where the recoil electron deposits its energy and the scattered photon undergoes a photoelectric absorption in the NaI(Tl) crystal of the Anger camera. The SDD is composed of a monolithic array of 19 hexagonal cells each having an on-chip transistor which provides the first stage amplification. /sup 137/Cs source has been finely collimated in order to study events occuring at different locations within a single cell. The equipment is designed such that the measurements can be done in all detector orientations and kinematical conditions. The angular and energy distribution of coincidence events have been studied with high statistics. Energy resolution and angle measurements performed with this detector system will be presented in this paper.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.