Abstract

BackgroundThis study reports the outcome of a plating system for arthrodesis of the first metatarsophalangeal joint (1st MTPJ) that incorporates a lag compression screw within a low profile titanium plate with a predetermined contour. This is the first report of the outcomes of this implant from a non-affiliated centre. Patient and methodsThis is a prospective cohort study of 40 consecutive primary 1st MTPJ arthrodesis procedures. The mean age of the cohort was 56 years (range, 20–74 years). The diagnosis was hallux rigidus in 31 patients and inflammatory arthropathy in 7 patients. ResultsAll patients achieved clinical union at 6 weeks and radiological union was confirmed on plain radiographs between 6–16 weeks. One case of hardware removal was reported. ConclusionThe cohort achieved consistently satisfactory results with a reliable and reproducible MTPJ position and a 100% union rate. There was a low rate of hardware removal. Level of evidenceLevel IV evidence. Prospective cohort study.