Abstract
This paper describes the development of time resolved particle image velocimetry (PIV) within the Department of Mechanical Engineering at the University of Strathclyde. The Department's first PIV systems were developed on a limited budget and used existing and second hand equipment. The original technique which, employed 16mm high speed cinematography, is described. The introduction and development of low cost systems employing high speed digital video (HSDV) is discussed and, finally, the Department's new time resolved PIV system, supplied by Dantec Dynamics, is introduced. For each of the PIV systems that have been developed a critical analysis of their functionality is given and samples of the data that they have been produced are shown. Data are presented from systems such as de-rotated centrifugal impellers, air bubbles growing in columns of water, pulsatile jets and vortex shedding.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.