Abstract

We present the case of an 85-year-old woman diagnosed with severe aortic stenosis, porcelain aorta, and a small aortic annulus (17.3 mm), who underwent successful transfemoral transcatheter aortic valve implantation (TAVI) with a 20-mm Edwards SAPIEN XT valve using the NovaFlex+ delivery system. At 1-month follow-up the patient was in NYHA functional class I, and Doppler echocardiography showed a mean residual gradient of 15 mm Hg and trivial paravalvular aortic regurgitation. This case, which shows for the first time the feasibility of TAVI with a 20-mm valve, opens a new avenue for the challenging treatment of patients with aortic stenosis and a small aortic annulus.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.