Abstract
The trans-catheter valve-in-valve concept has become a feasible therapeutic option for patients with failing degenerated bioprosthesis, who are deemed inoperable. However, little is known about the feasibility of this technique in failed valve annuloplasty. We report the first-in-man implantation of a trans-catheter aortic valve within a mitral annuloplasty ring. Through a trans-apical trans-catheter approach, a 26-mm Sapien-Edwards valve was successfully implanted in a 72-year-old man with ischemic heart failure and failed mitral-valve annuloplasty. The present case report provides a critical appraisal of the procedural technique.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.