Abstract

The CRIPT Cosmic Ray Imaging and Passive Tomography system began data taking in September 2012. CRIPT is a “proof of principle” muon tomography system originally proposed to inspect cargo in shipping containers and to determine the presence of special nuclear materials. CRIPT uses 4 layers of 2 m x 2 m scintillation counter trackers, each layer measuring two coordinates. Two layers are used to track the incoming muon and two for the outgoing muon allowing the trajectories of the muon to be determined. The target volume is divided into voxels, and a Point of Closest Approach algorithm is used to determine the number of scattering events in each voxel, producing a 3D image. The system has been tested with various targets of depleted uranium, lead bricks, and tungsten rods. Data on the positional resolution has been taken and the intrinsic resolution is unfolded with the help of a simulation using GEANT4. The next steps include incorporation of data from the spectrometer section, which will assist in determining the muon's momentum and improve the determination of the density of the target.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.