Abstract

Identification as well as quantification of ammonia are required in some analytical fields including forensic science. For this purpose, gas chromatography/mass spectrometry (GC/MS) analysis is one of the most suitable techniques. Although ammonia needs to be derivatized for GC/MS analysis, conventional derivatization reagents require anhydrous conditions because they are highly reactive with water. Here, we investigated ethenesulfonyl fluoride (ESF) as a selective reagent for ammonia derivatization in aqueous media to develop a rapid identification method for ammonia in aqueous media. The Michael addition reaction of ammonia with ESF rapidly produced a tri-ESF derivative suitable for GC/MS analysis. We optimized the derivatization reaction conditions and extraction solvent. With the optimized protocol, the detection limit for aqueous ammonia was 0.05 μg mL-1. The calibration curve showed good linearity (R2 = 0.9998) in the range of 0.10-100.0 μg mL-1, and the accuracy (% bias) and the precision (% relative standard deviation) for concentrations of 0.10, 0.25, 10.0, and 75.0 μg mL-1 were within ± 10% (intra- and inter-day). The proposed ESF-based method could quantify ammonia in samples containing interfering nucleophilic substances. This method was successfully applied to ammonia-containing commercial products.