Abstract

PurposeThis prospective, observational first in human study evaluated the safety and effectiveness of WRAPSODYTM Cell-impermeable Endoprosthesis (Merit Medical Systems, Inc.) in the treatment of arteriovenous fistula and arteriovenous graft access circuit stenosis.Materials and MethodsInvestigators conducted a prospective analysis of 46 patients with access circuit stenosis from three centres. Treatment sites included the peripheral outflow veins (e.g. cephalic arch, basilic vein swing point; 16 fistula and 10 graft patients); the graft-vein anastomosis (9 patients); and the central veins (up to, but not including the SVC; 11 patients). Primary outcome measures included 30-day freedom from access circuit-related safety events and 30-day target lesion primary patency. Secondary outcome measures included procedural success; device- and procedure-related adverse events; target lesion primary patency; access circuit primary patency; and secondary patency. In-person follow-up was scheduled at 1, 3, 6, and 12 months. An independent data monitoring/clinical event committee adjudicated all reinterventions and device/procedure-relatedness for adverse events.ResultsAll initial procedures were successful. All but one patient was free from safety events through the first 30 days (97.8% (45/46)). This event was not device-related. Over the remainder of the study, one adverse event was adjudicated as possibly device-related. Six- and 12-month target lesion primary patency rates were 97.7% (42/43) and 84.6.% (33/39), respectively. Six- and 12-month access circuit primary patency rates were 84.4% (38/45) and 65.9% (29/44), respectively.ConclusionResults suggest that the study device is safe and effective for treatment of stenoses in the peripheral and central veins of arteriovenous access circuits.Level of EvidenceLevel 2b, cohort study.

Highlights

  • This prospective, observational first in human study evaluated the safety and effectiveness of WRAPSODYTM Cell-impermeable Endoprosthesis (Merit Medical Systems, Inc.) in the treatment of arteriovenous fistula and arteriovenous graft access circuit stenosis

  • Secondary outcome measures included clinical, anatomical, and procedural success

  • As reported by the site and confirmed by the data monitoring/clinical event committee (DMC), this event was related to a preexisting perianastomotic seroma causing extrinsic compression near the inflow end of the circuit and not related to the study procedure or device

Read more

Summary

Introduction

This prospective, observational first in human study evaluated the safety and effectiveness of WRAPSODYTM Cell-impermeable Endoprosthesis (Merit Medical Systems, Inc.) in the treatment of arteriovenous fistula and arteriovenous graft access circuit stenosis. Materials and Methods Investigators conducted a prospective analysis of 46 patients with access circuit stenosis from three centres. Treatment sites included the peripheral outflow veins (e.g. cephalic arch, basilic vein swing point; 16 fistula and graft patients); the graft-vein anastomosis (9 patients); and the central veins (up to, but not including the SVC; patients). Primary outcome measures included 30-day freedom from access circuit-related safety events and 30-day target lesion primary patency. Secondary outcome measures included procedural success; device- and procedure-related adverse events

Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have